Sign In | Join Free | My himfr.com
Home > Presence Detectors Sensor >

Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting

Shenzhen Merrytek Technology Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting from wholesalers
     
    Buy cheap Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting from wholesalers
    • Buy cheap Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting from wholesalers
    • Buy cheap Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting from wholesalers
    • Buy cheap Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting from wholesalers
    • Buy cheap Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting from wholesalers

    Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting

    Ask Lasest Price
    Brand Name : Merrytek
    Model Number : MSA012
    Certification : CE RoHS
    Price : Negotiation
    Payment Terms : T/T, Western Union
    Supply Ability : 10,000pcs per Month
    Delivery Time : within 5 working days for sample and small order; within 3-4 weeks for bulk order
    • Product Details
    • Company Profile

    Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting

    Microwave Motion Sensor Stand-alone Minor Motion Sensor with Daylight Harvesting for Office Application MSA012



    1. Features

    1) Adopt Merrytek patented Minor motion detecting technology for small movement ,suitable for offices, conference rooms, classrooms and other applications


    2) Anti air conditioning, fans and other interference;


    3) Built-in daylight harvesting technology to achieve accurate constant light


    4) Parameters can be adjusted by remote control or DIP switch


    5) Equipped with infrared remote control, the transmitting Angle can be adjusted to accurately adjust the target sensor;


    6) Wide voltage 120-277vac input, common in European and American markets;


    7) Supports flush-mounted stand-alone installation


    2. Parameters


    InputOperating voltage108-305VAC 50/60Hz
    Rated voltage120V/277VAC 50/60Hz
    Stand-by power<1W
    Surge testN—L: 1kV
    OutputWorking modeON/OFF 1-10V dimming
    Type of loadInductive or resistive
    Load capacity

    400W (Inductive) 800W (resistive) @120V AC

    800W (Inductive) 1000W (resistive) @277v AC

    Max.surge capacity50A (50% Ipeak, twidth =500uS, 277Vac full load, cold start); 80A (50% Ipeak, twidth =200uS, 277Vac, full load, cold start)
    Dim interface1-10V Dimming< 50mA(Non-constant source)
    wiring modePress the terminal
    Sensor parametersOperating frequency5.8 GHz ±75 MHz,ISM band
    Transmitting power0.5mW Max.
    Hold time

    5S/30S/1min/3min/20min/30min

    (remote control Settings: 30 s / 5 s / 1 min / 3 min / 5 min, 10 min / 20 min / 30 min)

    Stand-by dim Level10/20/30/50% (remote control setting: 10/20/30/50%)
    Stand-by Period

    0 s / 1 min / 3 min / 10 min / 30 min / + up

    (remote control Settings: 0 s / 10 s / 1 min / 3 min / 5 min, 10 min / 30 min/Disable)

    Detection Area100%/50%(remote control Settings:100%/75%/50%/25%)
    Daylight Sensor5lux/15Lux/30Lux/50Lux/100lux/150lux/Disable
    Detection range (radius)3-5m (ceiling mounting;3m)
    Mounting heightsupport 6m Max.
    Detecting Angle150°(wall mounting) 360°(ceiling mounting)
    Operating envrionmentOperating Temperature-25℃…+55℃ Humidity: 85% (non-dew)
    Storage Temperature/humidity-40℃…+80℃ Humidity: 85% (non-dew)
    Certificate StandardsSafety standardsEN61058-1
    Environmental RequirementCompliant to RoHS
    CertificateCE RoHS
    OthersWiring"L N ground" port diameter: 0.75-1.5 mm2 "1-10v" port diameter: 0.75-1.0 mm2
    IP RatingIP20
    Protection ClassClass II
    InstallationBuilt-in
    Installation imensionØ70-Ø80
    PackageWhite box + flat card + outer box (K=A)
    Net weight153.2g
    Life time50000h @ Ta full load
    Note 1. “N/A”means not available. 2. Detection area is effected on volume of motion object and motion speed. The detection area is tested by a 165cm height person and walking speed is 0.5m/s

    3.Function


    People's normal working life in the body gentle motion sensing, in non-sleep conditions to achieve approximate human presence detection.



    A. On-off function (WITHOUT DH)



    B. 2 step dimming function (WITHOUT DH)

    C. 3 step dimming function (WITHOUT DH)


    D. On-off function (WITH DH)

    E. 2 Step dimming function (WITH DH)

    F. 3 Step dimming function (WITH DH)



    4.Dimension (mm)

    5. Wiring

    *The sensor is recommend to connect one load only. Connect more than one loads need to consider the load and surge capacity.


    6. Structure




    7. Detection pattern


    1)Ceiling mounting


    Horizontal installation: 3m Sensor range setting:

    100%/75%/50%/25%

    Horizontal installation:6m

    Sensor range setting:

    100%/75%/50%/25%


    8. Dip switch settings


    The control of indicator light

    1
    ONTest
    -Normal

    Detection Area

    2
    ON100%
    -50%

    Hold Time

    345
    ONONON5S
    -ONON30s
    ON-ON1min
    --ON3min
    ONON-20min
    ---30min

    Stand-by Period

    123
    ONONON0S
    -ONON1min
    ON-ON3min
    --ON10min
    ONON-30min
    ---+∞


    Daylight Sensor

    6789
    ONONONON5Lux
    -ONONON15Lux
    ON-ONON30Lux
    --ONON50lux
    ONON-ON100lux
    ONONON-150lux
    VII----Disable

    Stand-by DIM Level

    45brightnessConstant voltage output
    ONON10%1.5±0.1V
    ON-20%2V±0.1V
    -ON30%3V±0.1V
    -50%5V±0.1V

    9. Remote control


    10. Canceling the sensor function

    The sensor function can be canceled by quick Switching off/on 3 times within 2 seconds. Turn off/on the power again to recover sensor function .


    11. Initialization

    The light will turn on 100% brightness in the initial energizing sensor, and turn to low brightness 10 seconds later (the brightness set by stand-by dim level). During initialization, no external motion sensing signal will be detected.


    12. Factory setting

    The control of indicator light:normal Detection Area:100% Hold Time:5S Daylight Sensor:Disable Stand-by Period: 0S Stand-by DIM Level:10%


    13. Application notice

    1. The interval between multiple installations is 3m.

    2. The use of Daylight harvesting functions need to use with MH10 remote control to use.

    3. The product is switched on and off three times in a row within 2S, and the product enters the normally bright mode.

    4. The product is set by remote control. After each setting is successful, the load light will flash once, which means the setting is successful.

    5. There should be no metal plate, glass cover and other materials with high medium density in front of the sensor, which is easy to trigger by mistake.

    6. If it cannot be installed in a room that vibrates for a long time, the vibration signal will be regarded as a mobile signal to trigger the sensor.

    7. Turn off the indicator light in normal use to avoid affecting the constant light control!The first dial code needs to be set to OFF state


    Quality Stand Alone 277VAC Minor Motion Sensor With Daylight Harvesting for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Merrytek Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)